CATL Pairs Truck Battery Swaps With 77 kWh Backup Pack

CATL's truck battery system combines a swappable main pack with a permanent backup, aiming to unlock more usable energy and seasonal leasing savings.

Angela Marino 3 min read
firetruck, fire, emergency, siren, fire department, rescue, firefighter, firetruck, firetruck, fire, emergency, emergency, fi

CATL unveiled a dual-battery system for battery-swapping heavy trucks, with agreements for 13,000 units signed at the launch.

CATL is pairing a swappable truck battery with a permanent 77 kWh backup pack, seeking to let freight operators use more of their main battery’s charge before returning to a swapping station. Agreements for 13,000 units were signed at the unveiling.

The design combines a standardized, chassis-mounted battery from QIJI Energy, CATL’s heavy-truck battery-swapping network, with a separate power system behind the cab. The backup is intended to address drivers’ reluctance to run the main pack close to empty, while a seasonal leasing option targets battery rental expenses.

The launch and agreements were reported by Charged EVs. The agreements represent a commercial commitment at the unveiling, rather than completed truck deployments.

A backup pack makes more main-battery energy usable

CATL says drivers of conventional battery-swapping trucks often arrive for a replacement with unused energy because they are unwilling to discharge the main pack deeply. Its new system is designed to increase the main battery’s depth of discharge—the share of its capacity used—from about 70% to more than 95%.

Its new system is designed to increase the main battery’s depth of discharge—the share of its capacity used—from about 70% to more than 95%.

That would allow the main pack to reach a swapping station with less than 5% charge remaining. CATL says its switching technology transfers power delivery to the backup battery within milliseconds. The operating benefit therefore depends partly on drivers becoming comfortable using energy they previously kept in reserve.

The backup battery supports 3C charging, a charging-rate designation measured relative to battery capacity. It can be tailored for energy density, cold-weather operation or power requirements, while the main pack remains compatible with QIJI’s swapping network. The batteries can also be developed and upgraded independently.

This separates route-specific requirements from the standardized equipment handled by swapping stations. A fleet can customize the battery that stays on the truck without requiring the interchangeable main pack to follow the same design.

Seasonal leasing separates ownership from freight demand

The range-extension battery is independently owned and remains with the vehicle throughout its service life. The main battery, by contrast, can be leased according to seasonal freight demand, giving operators a way to reduce rental commitments during quieter periods.

QIJI has also introduced standardized 260# and 300# swapping blocks, with capacities of 432 kWh and 513 kWh, alongside its existing 75# block. The broader selection is intended to accommodate different truck models and operating conditions. QIJI says a swap takes five minutes and reports a first-attempt success rate of 99.99%.

Under its battery-as-a-service model, QIJI bills customers for net energy charged rather than energy discharged, allowing them to retain the value of electricity recovered through regenerative braking. It says that billing approach reduces battery rental costs per kWh by up to 20% for customers on basic plans.

That claim concerns a specific rental-cost measure, not total fleet operating costs. The commercial proposition combines deeper use of the main battery, rapid swapping and more flexible rental arrangements; each addresses a different part of a truck operator’s energy and equipment bill.

Key facts

  • Launch agreements: 13,000 units
  • Backup battery: 77 kWh capacity with 3C charging capability
  • Main battery utilization: CATL says depth of discharge rises from about 70% to over 95%
  • Rental-cost claim: QIJI says basic-plan battery rental costs per kWh fall by up to 20%